Brand |
Glory Diagnostics
|
Overall Performance |
Equipment type : Fully automatic, discrete, STAT priority
Analysis rate : Colorimetry speed 240T/H (single/double reagent)
Test principle : Colorimetry, turbidimetry
Analysis method : End-point, kinetics, fixed-time, etc.
Support single/double wavelength and 1-2 multiple reagent item
linear and non-linear calibration
|
Sample reagent unit |
Sample reagent position : The reagent and sample share one disk, totally 67 positions.
Continuously cooling at all positions to keep 5-15°C within 24 hours
Sample cuvettes specification : Standard cup, original blood tube, multi-specification tube available (012~16)mmx(25~1OO)mm
Sample volume : 3pl~35pl,0.1pl stepping
Reagent volume : R1:10pl~350pl, R2:10pl ~200pl , 1pl stepping
Sample reagent probe : 1, with the function of liquid level detection and collision detection
Sample reagent probe carrying rate : Automatic warm water cleaning. Carrying rate <0.1%
Automatic sample : dilution 3-115
|
Reaction unit |
Reaction cuvette : 120 positions optical plastic cup, optical diameter is 6 mm
Total volume of reaction : liquid 150pl ~ 550pl
Reaction temperature : 37°C , ±0.1°C
Reaction disk constant temperature : Circulating water
Mixer : 1, after joining reagent, blending immediately
Reaction cuvette cleaning : 8 stops 12 steps by warm water rinsing
Wastewater treatment : With the function of concentrated waste liquid level alarming
|
Optical system |
Light source : 20W/12V halogen lamps
Monochromator : Grating photometry
Photoelectron road After spectrophotometry
Wavelengths : 340nm, 380nm, 405nm, 450nm, 480nm, 505nm, 546nm 570nm, 600nm, 660nm, 700nm, 750nmor 800nm
Detector : Photodiode LED array
OD linear range : 0 ~ 3.3Abs
|
Calibration and QC |
Calibration method : 1 point linear method, 2 point linear method, multiple point linear method, non-linear method
Calibration tracking : Automatic description calibration K-value trends
QC Method : Real-time QC, individual QC and monthly QC
Out of control processing : Alarming for out of control sample, record lost control reason
|
Operating System |
PC operating system : Windows XP
Analysis control software : Graphical operating software english version
Main function of software : Automatic calibration, automatic barcode scanning, item compounding
test, reagent info management, serum index, whole reaction process
monitoring, dirty cup memory evading, prevent cross-contamination
procedure, patient information memory and association input, automatic
report audit, data multiple parameter query, report format statistic and
printing, reference range classification, alarming information
classification, user operating right classification, automatic dormancy
and wake, real-time online help
Report printing : Report formats support the user-defined mode, QC and state information etc.
PC configuration : CPU >2.2GHz(dual-core processor); Memory >1G; Harddisk > 160G;
17 inch LCD display; Stylus, inkjet or laser printer (optional)
System connection : TCP/IP network connection, standard RS-232C
|
Others |
Volume : 998mmx752mmx517mm
Weight : 120kg
Power supply : Voltage AC 220V±22V, 50/60Hz, power 650VA
|